Active Harmonic Filter

Active Harmonic Filter(AHF) is a perfect comprehensive solution to power quality problems such as harmonic wave, reactive power, and 3 phase load unbalance. AHF is connected in parallel in the power grid, to detect the harmonic wave in real time, generate the reverse-phase compensation current through the converter, and dynamically filter the harmonic wave. The operation of AHF is unaffected by power grid structure and load type, and it will not produce harmonic oscillation with the system, thus perfectly realizing harmonic wave control of various loads. AHF can also realize dynamic reactive compensation, and control the capacitor switching, to improve the power factor. Meanwhile, Active Harmonic Filter has the function of controlling the 3 phase load current unbalance, thus comprehensively solving various power quality problems with the power grid.

Key Features of Active Harmonic Filter

  • Multifunctional: Harmonic, reactive power and imbalance compensation
  • High harmonic filtering rate: Up to 98%
  • Excellent reactive compensation: High speed, Precise (-0.99≤PF≤0.99), Step-less, Bi-directional (capacitive and inductance) compensation
  • Excellent imbalance correction: Both negative and zero sequence, mitigates neutral current
  • Wide input voltage & frequency range, adapts to tough electrical environments
  • Low thermal loss (≤3% of rated AHF kVA), efficiency ≥ 97%
  • High stability: Infinite impedance to grid, avoids harmonic resonance problems
  • Flexible application: Modular design, embedded in standard or customized cabinet
  • Easy installation and maintenance: Plug-in installation for AHF module replacement and expansion
  • Wide capacity range: 30A~600A for a single cabinet, up 10 cabinets in parallel
  • Environmental adaptability: -10~50°C temperature, compatible with diesel generator
  • Complete protection: Grid Over/Under voltage, AHF over current, over temperature, and more. All faults are recorded in the event log, which is convenient for failure analysis

Typical Application of Active Harmonic Filter

Harmonics occur usually as follows,

  • Overheating of transformers and conductors
  • Generator instability
  • Capacitor failure
  • Nuisance tripping of fuses and circuit breakers
  • Damage to or failure of sensitive electronic equipment including drive failure
  • Telephone interference
  • Motors experiencing overheating, audible noise and reduced service life
  • High energy costs
  • Downtime and loss of production due to equipment instability.

AHF Modular Datasheet

Number of phases (system input) 3-phase 3-wire or 3-phase 4-wire
Rated frequency 50/60Hz
Rated voltage 400 V ±20%
Response time <5ms
Harmonic mitigation performance 2nd to 50th harmonic
Filter Efficiency >97%
Total harmonic current distortion (THDi) ≤ 5%
Reactive power compensation Rate >0.98 (inductive and capacitive compensation)
3 phase unbalance compensation effect <5%
Active Loss of system <3%
Inverter topology IGBT
Controller DSP + FPGA
Current transformer placement Mains side or load side
Communication interface Modbus Protocol, RS485
Rated current of Modular 30A 50A 75A 100A 150A
Weight 30kg 30kg 35kg 40kg 45kg
Self-protection Yes
Over heat protection Yes
Over/under voltage protection Yes
Over/under frequency protection Yes
Noise level <60 dB (depending on load situation)
Relative humidity <95% non-condensing
Temperature -20 ~ 70°C
Cooling type Air cooling
Dimensions cabinet 440 mm × 641 mm × 230.5 mm (W × D × H)
Mounting Wall-mounted or Rack mounted
Ambient conditions <1000m; Up to 4000m with derating 1% per 100m
Protection class IP20
Certification ISO9001, Type Test Report
EN 50178:1997 / IEC50178:1997
Design standards EN61000-6-2 (2005) / EN55011, Group 1, Class A
IEC61000-6-2 (1999) / CISPR11, Group 1, Class A
EN50091-3 / IEC62040-3 / AS62040-3 (VFI SS 111)

Our Certificates

Our Certificates

CE

ISO

MSME

ISO

Ready to Upgrade Your Production Quality?

If you are interested in our products and want to know more details, please leave a message here, we will reply you as soon as we can.

Get in Touch with Us

    Improve Your Power Performance. Call Us Today!